PDU socket for many smart home and electricians are not unfamiliar, but for small white like Xiaobian is really confused, and think it is no different from ordinary socket. Let's find out the difference between them!
PDU socket is the first and the most close part of the operation of many equipment, and the quality of PDU socket directly affects the quality of each equipment. PDU socket series cabinet socket type power protection lightning arrester is designed according to IEC standard, which is specially used for fine protection of single-phase AC power supply sensitive equipment. It is applied to the equipment end as the third level protection of power supply, so as to prevent the equipment from the damage of transient overvoltage caused by lightning stroke or electronic interference. The power supply protection lightning protection device adopts two-stage series linkage protection, the maximum flow rate can reach 20KA, the voltage protection level can be as low as 800V, the input and output are compatible with multi-national standard plug and various power matching, with recoverable overload protection device, which perfectly combines the lightning protector and power plug-in board.
PDU power socket is generally used in data center, power distribution room, industrial factories and mines, production workshops, computer rooms and enterprise shopping malls and other fields.
Difference between PDU and common socket
Different load power
The cable configuration load of common socket is relatively weak, and most of them are rated 10A. If 1.5mm2 cable is used, a few manufacturers will nominal 16a4000w. According to the national cable and wire standards, the rated bearing power of ordinary socket is difficult to achieve more than 4000W in any configuration. It can be seen that it is difficult to meet the requirements of the computer room which is growing rapidly.
Pdu-08 8-way PDU socket
PDU socket (power distribution unit) is undoubtedly to a large extent to solve this problem, because any of its components can be customized, which can fully meet the safety of the electrical environment of the computer room. At present, the industrial plug is more and more widely used in PDU socket, and its current number can meet the requirements of 16a, 32a, 65A, 125A and so on. Therefore, it is very wrong to use the ordinary non professional socket on the cabinet.
Different materials
Ordinary socket is generally plastic, while PDU socket is all metal. If the load is too large, the PDU socket has the fire protection function, but the ordinary socket does not. As the PDU socket is a metal shell, it has the function of anti-static, which can protect sensitive electronic equipment from electrostatic hazards. So as to protect the stable operation of the equipment.
Different functions
The common socket only has the function of power overload and general control, and the output of Jack is very monotonous.
The PDU socket not only has many functions (lightning protection function, master control switch, overload protection, current and voltage display, remote monitoring function, online detection of smoke temperature and humidity, etc.), but also the output module can be reasonably matched and selected according to the specific situation. (national standard, American Standard, international IEC, German standard, etc.)
Life span gap
Ordinary socket is usually 2-3 years. About 4500-5000 plug.
PDU socket is made of super conductive metal material -- tin (phosphorus) bronze. It has good wear resistance and conductivity. The temperature rise is only 20 ℃ when it is electrified at full load for one hour, which is far lower than the national standard of 45 ℃. Hot swap is more than 10000, and the service life is up to 10 years, which is more than 5 times of the ordinary socket.
One
PDU-08
8-way PDU insertion
8-loop universal socket output;
The maximum output current of single circuit is 10a, and the total input current is 10A;
19 inch standard cabinet 1U design.
Two
IPCS-0610
Intelligent PDU timing insertion
The 6-channel switch can be independently controlled and displayed by the panel;
Multiple devices can be cascaded with RS232 and Io,
Realize the function of sequential switch among multiple devices.